im体育APP’s electrochemical 腐蚀测试 helps prevent harmful interactions between various metals and the environment. We assess corrosion susceptibility using a wide range of methods, such as electrochemical impedance spectroscopy, to provide you with fast and accurate performance data. 

From analyzing finished products to comparison of raw materials, our electrochemical 腐蚀测试 can be used in many applications. im体育APP’s 从事专家 solve your problems related to materials selection, degradation mechanisms and failure analysis in a range of industries including 石油 & 气体, 医疗设备, construction, manufacturing, utilities, chemical and petrochemical, and electronics.

 

Our Electrochemical Corrosion test methods

  • Electrochemical Impedance Spectroscopy (EIS) ISO 16773
  • Cyclic potentiodynamic polarization testing for medical devices ASTM F2129
  • Calculations of corrosion rates ASTM G102
  • Polarization resistance ASTM G5, G59, G61
  • Galvanic current measurement and monitoring Astm g71 (g82)
  • Pitting and crevice corrosion resistance measurement ASTM G5, G150
  • Electrochemical reactivation (sensitization of stainless steels) ASTM G108
  • Corrosion potential measurements ASTM G69
  • Linear Polarization Resistance (LPR)
  • High-temperature electrochemical testing

In addition to electromechanical 腐蚀测试, our experts utilize their experience in 腐蚀测试 对金属, 合金, paints and coatings to offer you customized testing according to your need and fit for your budget and provide support for every stage of testing. 

 

The im体育APP advantage

Our corrosion experts combine industry experience with state-of-the-art corrosion laboratory testing. As a trusted partner for materials testing, you can be confident that the results you receive from im体育APP are accurate, reliable and right the first time.

For more information about how we perform Electrochemical Corrosion 测试, or to request a quote, 立即im体育APP.

Electrochemical Corrosion 测试 640 x 480 May 2018
Electrochemical Corrosion testing

ASTM F2129 Electrochemical Corrosion testing of medical devices

im体育APP performs electrochemical 腐蚀测试 per ASTM F2129 to ensure that medical devices are safe, and provided the intended benefits to the patient.

The human body is a corrosive environment for any metallic implantable device. In addition to causing device failure, chemical interactions between the body and a device can have harmful biological consequences. Our electrochemical corrosion labs use cyclic potentiodynamic polarization methods to simulate the biological environment, helping to detect and address issues in the lab before they become failures in the body.

Our team of over 9,000 从事专家 in North America, 欧洲, 中东地区, 澳大利亚, Asia and Africa are ready to help you.